R-Value Calculator

Layering two materials? Enter the thickness of each. You get the total R-value, the RSI and the U-factor.

Your shopping list

11.2 RTotal R-value
1.97RSI (metric)
8.93 Btu/h per FHeat loss per 100 sq ft
  • U-factor1 divided by R0.09

Framing lowers the R-value of a whole wall, so a real wall tests lower than this sum.

How to use the R-Value Calculator

  1. Pick the first material and its thickness.
  2. Pick the second layer, or leave it at none.
  3. Add extra R for drywall and air films if you want, then read the total.

The math behind it

R of a layer = thickness x R-value per inch
Total R = R1 + R2 + extra R
U-factor = 1 / total R, RSI = total R / 5.678

A worked example

What we typed in

  • First layer material: Fiberglass batt (about R-3.2 per in)
  • First layer thickness: 3.5 in
  • Second layer material: XPS foam board (about R-5 per in)
  • Second layer thickness: 1 in
  • Extra R-value (drywall, air films): 0

What we got

  • Total R-value: 16.2 R
  • RSI (metric): 2.85
  • Heat loss per 100 sq ft: 6.17 Btu/h per F
  • U-factor: 0.06

Tips from the job site

  • Add the R-values of layers in a row. Do not average them.
  • Framing lowers the whole wall R-value, so a real wall tests lower than this sum.

Common questions

How do I add R-values?

Add them up for every layer the heat passes through in a row.

What is a U-factor?

It is 1 divided by the R-value. A lower U-factor means a better wall.

See all Insulation Calculators.